EATON UPS FOR LARGE BUSINESSES, CORPORATIONS & DATA CENTRES

Borri B8000 (10-40 kVA)

The B8000 series is a transformerless UPS with IGBT input and output technology. The combination of Isolated Gate Bipolar Transistors (IGBT) and digital processing (DSP) enables the B8000 series to have an almost negligible effect on the mains supply, providing less than 3% harmonic distortion.

When running in its normal On-Line mode, the B8000 offers AC/AC efficiency of 95% increasing to 98% in DC to AC mode. Achieving such a high DC to AC efficiency means that the batteries and your network run for longer. Should "SOL (Smart Online Mode)" be selected AC to AC efficiency increases to approximately 98%. The B8000's special features dramatically reduce service and repair times, as all problems are diagnosed via the LCD display.

More Info

Borri B9000 (60-300 kVA)

The B9000 is one of the most efficient uninterruptible power supplies available on the UPS market. The B9000 is typically 7% to 8% higher than conventional six pulse UPS, providing a massive efficiency saving for the user. The B9000 can be configured to operate in parallel, offering an N+1 configuration or alternatively as a power expansion option. The parallel control system tightly manages both active and reactive type loads, allowing for intelligent load/current sharing between each individual phase.

To offset unavoidable battery decay, the B9000 incorporates a battery management system that is calibrated in accordance with most battery manufacturer's specifications including NiCad's. The B9000 is suitable for almost any type of load accepting a power factor of either 0.9 leading or 0.9 lagging (many other manufacturers standard is 0.8pf).

More Info

Borri 9600 (400-800 kVA)

The B9600 is one of the most efficient uninterruptible power supplies available on the UPS market. The innovation and design of the B9600 has resulted in it being the most technologically advanced UPS in its class. It delivers an incredible combination of low input current distortion and unity power factor. The benefits of these advances make the B9600 a hugely desirable UPS for any company requiring high power efficiency.

The B9600 is designed with an IGBT rectifier and an advanced PFC (Power Factor Control) keeping harmonic distortion at less than 3%. The On-Line Double Conversion Technology isolates output power from all the input anomalies, providing a clean output. The parallel control system tightly manages both active and reactive type loads, allowing for intelligent load/current sharing between each individual phase.

To offset unavoidable battery decay, the B9600 incorporates a battery management system that is calibrated in accordance with most battery manufacturer's specifications. The B9600 is suitable for almost any type of load accepting a power factor of either 0.9 leading or 0.9 lagging (many other manufacturers standard is 0.8pf).